SERVICING INSTRUCTIONS
FAULT FINDING
30
EVIDENCE OF FAULT CAUSE
Impossible to set high fire low enough
1. Too much primary air
Impossibletosetlowrehighenough 1. Too little primary air
Impossibletosetlowrelowenough 1. Too much primary air
Oil smell apparent 1. Too little primary air
2.Toolowauepull
3.Downdraughtintheue.Fitsuitableanti-downdraughtcowl
4. Flue partly or fully blocked
5.Highrescrewsettoohigh
Black stain around any door 1. Too little primary air
2.Toolowauepull
3.Downdraughtintheue.Fitsuitableanti-downdraughtcowl
4. Flue partly or fully blocked
5.Highrescrewsettoohigh
Burner carbons up after short period 1.Lowrescrewsettoolow
2.OilControllterblocked.Removeandcleanwithboilingwater
and dry thoroughly before replacing
3. Incorrect or contaminated fuel. A small amount of contamination
cancausetrouble.Cleanouttankandrellwithanewfuel
Unable to light burner 1. Control metering stem slot obstructed. To clear, turn Control
Knob from OFF to full ON several times
2. Oil Control Filer blocked. Remove and clean with boiling water
and dry thoroughly before replacing.
3. Metering stem in oil control sticking. Replace control
4. Fuel inlet blocked. Service.
5. Oil depth in burner base too shallow.
6. Oil level in tank too low
7. Air lock in oil line tank - burner - control
8. Incorrect or contaminated fuel. A small amount of contamination
cancausetrouble.Cleanouttankandrellwithanewfuel
9. Isolation valve at tank shut
10.OilControlvalveoodedandInletValveclosed
Comentários a estes Manuais